			Phase sequence 
			relay BA 9041, AI 941 N  
			
			
			 • 
			According to IEC 255, EN 60 255, VDE 0435 part 303• 
			Detection pof wrong phase sequence
 • 
			1 or 2 changeover contacts
 • 
			Width 45 mm.
 
 ÃÒÂÅÐàÍÕ´
 | 
          
            
          | 
			 | 
			Asymmetry 
			realy BA9042,AI942 
			
			
			 • 
			According to IEC 255, VDE 0435 part 303• 
			For nominal voltage from 3 AC 230 V to 500
 • 
			Detection of
 - voltage asymmetry
 - wrong phase sequence
 - phase failure
 • 
			Detection of feedback voltage
 •
			BA 9042 optionally with ajdustable time delay
 • 
			Closed circuit operation
 • BA 9042 LED indicators for operation and state of cantacts
 • 2 LED displays for power supply and state of contact
 •
			Width 45 mm
 Standard Type: BA 9042 3 AC 400V 50/60 Hz
 Article number: 0040770
 stock item
 - Output: 2 changeover contacts
 - Nominal voltage UN: 3 AC 400
 - Output: 2 changeover contacts
 - Nominal voltage UN: 
			3 AC 400V
 - Width: 45 mm
 
			                                                                          
			
			                  
			
			ÃÒÂÅÐàÍÕ´ | 
          
            
          | 
			 | 
			Under voltage  
			realy BA9043,AA9943 
			
			
			 • 
			According to IEC 255, VDE 0435 part 303• 
			3-phase
 • 
			For nominal voltage of 3 AC 100/57 to 690/400V
 • 
			Measures arithmetic mean value
 • 
			Adiustable operate and release value
 • 
			For  3p3w or 3p4w systems
 • 
			BA 9043 optionally with adiustable time delay
 •
			Closed circuit operation
 • 
			LED indicator for operation and state of contact
 • Insensitive to hermonics
 • Frequency up to 400 Hz
 •
			Width 45 mm
 ÃÒÂÅÐàÍÕ´
 | 
          
            
          | 
			 | 
			Thermistor 
			motor protection relay BA9038, AI938 
			
			
			 • 
			According to DIN VDE 0660 part 302 ( pr EN 60 947-8 )and part 303
 • 
			1 input for PTC-resistors or bimetal contacts
 • 
			Broken wire dtdection in sensor ciruit
 • 
			Optionally with no voltage reclosing interlock
 • 
			Closed circuit operation
 • 
			1 or 2 changeover contacts
 •
			Width 45 mm
 ÃÒÂÅÐàÍÕ´
 | 
          
            
          | 
			 | 
			Current relay 
			BA 9053, MK 9053 
			
			
			 • 
			According to IEC 255, EN 60 255, VDE 0435 part 303• 
			to: monitor DC and AC
 • 
			Measuring ranges from 2 ma to  25 A
 • 
			BA 9053 with galvanic separated DC auxiliary supplay
 • 
			High overload possible
 • 
			Input frequency up to 5 kHz
 • 
			with time delay, up to max. 100 sec
 •
			BA 9053 optionally with 3 current ranges 0,1 to 25A
 • 
			BA 9053 optionally with safe separation to IEC/EN 61 140
 IEC/EN 60 947-1
 • BA 9053 as option with start - up delay
 •
			BA 9053 as option with manual reset
 • 
			MK 9053N optionally with remote potentiometer
 • LED 
			indicators for operation and contact position
 • Width KK 9053N: 22,5 mm
 Width BA 9053:     
			45 mm
 ÃÒÂÅÐàÍÕ´
 | 
          
            
          | 
			 | 
			Voltage relay 
			BA 9054, MK 9054  
			
			
			 • 
			According to IEC/EN 60 255, DIN VDE 0435-303 • 
			to: monitor DC and AC Voltage
 • 
			Measuring ranges from 15 mV to  500 V
 • 
			High overload possible
 • 
			Input frequency up to 5 kHz
 • 
			with time delay
 • 
			LED indicators for operation and contact position
 •
			BA 9054 optionally with galvenic separated DC auxiliary supply
 • 
			MR 9054 optionally with remote potentiometer
 • 
			BA 9054 as option with start-up delay
 • BA 9054 as option with manual reset
 • Width MK 9054N:  22,5 mm
 • 
			Width BA 9054         45 mm
 ÃÒÂÅÐàÍÕ´
 | 
          
            
          | 
			 | 
			Phase monitor 
			BD 9080 
			
			
			 • 
			According to IEC/EN 60 255, DIN VDE 0435-303• 
			Monitoring of
 - Under - and overvoltage
 - Asymmetry
 - Phase sequence
 • 
			Release time adjustable between 0,1 ... 5 s
 • 
			One LED in each case for
 - Auxliiary voltage A1/A2
 - Overvoltage Umax
 - Undervoltage Umax
 - Asymmetry / Phase sequence / Power failure
 - Contact position
 • 
			Closed circuit operation
 • 
			Available opencircuit operation
 • 
			2 changeover contacts
 • 
			Width 45 mm
 
			                                                                                            
			 ÃÒÂÅÐàÍÕ´ | 
          
            
          | 
			 | 
			Latching relay 
			AD 8851 
			
			
			 • 
			According to IEC/EN 61 810-1• 
			Manual operation possible
 • 
			Contact position indication via control lever
 • 
			max. 4 NC contacts, 4 NO contacts
 • 
			Width 45 mm
 
			                                                                         
			
			                  
			
			ÃÒÂÅÐàÍÕ´ | 
          
            
          | 
			 | 
			Insulation 
			monitor IL 5881, SL 5881 varmeter 
			
			
			 • 
			According to IEC/EN 61 557• 
			For DC voltage systems up to 12 ... 280V
 • 
			Wide voltage range of measuring input UNDC 12 .... 280V
 ( on request DC 24 ... 500V with 
			separate auxiliary supply
 Measuring range 20 ... 500 kΩ )
 • 
			Adjustable tripping value RAL of 5 ... 200 kΩ
 • 
			Selective ground fault indication for L+ and L- allows fast fault 
			fitding
 •
			Without auxiliary supply
 • 
			De-energised on trip
 • 
			2 changeover contacts
 • Automatic manual reset, programmable
 • With test and resent buttons
 • 
			Connection for external test and resent button possible
 • galvanic 
			separated AC or DC auxiliary supplay available as option
 • adjustable time delay as option
 • 
			2 models available:
 IL 
			5881:     61 mm deep with terminals to the 
			bottom to be
 mounted in consumer units or industrial distribution
 systems according to DIN 43 880
 SL 5881:     98 mm deep with terminals 
			near to the top to be
 mounted in cabinets with mounting plate and cable
 ducts
 • 35 mm width
 ÃÒÂÅÐàÍÕ´
 | 
          
            
          | 
			 | 
			Under voltage 
			relay IK9171 / IL9171 SK9171, SL9171, 3-phase 
			
			
			 • 
			According to IEC/EN 60 225, DIN VDE 0435-303• 
			Devices available in 2 enclosure versions:
 I-model: depth 59 mm, with terminals at the bottom for
 Installation systems and industrial distribution
 systems according to DIN 43 880
 S-model: depth 98 mm, with terminals at the top for cabinets
 with mounting plate and cable duct
 •
			Monitoring of undervoltage in 3-phase system
 • 
			Also for single phase
 • 
			Without auxiliary supply
 • Optionally for 3p 3w systems
 • Independent of phase sequence
 • 1 or 2 
			changeover contacts
 • Optionlly 
			fixed or settable response value
 • As option with phase sequence detection
 • 
			optionally with or without N
 • 
			Optionally with off-delay t1
 •  
			Optionally with on-delay t2
 • Width:
 • IK 
			9171, SK 9171 :      17,5 mm
 • IL 
			9171, SL 
			 9171 
			:        35 mm
 ÃÒÂÅÐàÍÕ´
 |